Sale!
SIP.V1340

1340 Litre Vertical Plastic Single Skin Oil Tank

Rated 0 out of 5
(0 reviews)

Due to extremely high current demand for oil tanks, our standard quick delivery service is taking longer than usual. Transport & production are both at maximum capacity. Please call the office to discuss your requirements & we will do our best to facilitate your needs but our standard lead times at present on this tank is 5 to 10 working days. Tel: 0330 999 1100

£437.00 Ex VAT£524.40 Inc VAT

5 in stock

You may also need

Contents Gauge:

Clock face tank contents gauge
Clock Face Tank Contents Gauge 4ft

£24.00 Ex VAT£28.80 Inc VAT

Watchman Sonic Tank Contents Gauge
Watchman Sonic Tank Contents Gauge

£128.00 Ex VAT£153.60 Inc VAT

Bottom Outlet Filter Pack

Advanced Filter Pack
Advanced Filter Pack

£48.00 Ex VAT£57.60 Inc VAT

Advanced 90 Degree Filter Pack
Advanced 90 Degree Filter Pack

£56.00 Ex VAT£67.20 Inc VAT

Advanced 90 Degree Tee Filter Pack
Advanced 90 Degree Tee Filter Pack

£106.00 Ex VAT£127.20 Inc VAT

Advanced Straight Tee Filter Pack
Advanced Straight Tee Filter Pack

£99.00 Ex VAT£118.80 Inc VAT

Advanced Parallel Tee Filter Pack
Advanced Parallel Tee Filter Pack

£114.00 Ex VAT£136.80 Inc VAT

This tank has required sections which must be completed before you can add to basket.

SKU: SIP.V1340 Category:

Description

1340 Litre Vertical Plastic Single Skin Oil Tank – SIP.V1340
Tank:

A 1340 litre vertical plastic single skin oil tank which is suitable for certain domestic installations only.

This tank is suitable for the storage of heating oil, kerosene, diesel, and certain other liquids (please check before usage).

This tank is manufactured in the UK and is moulded from Polyethylene using a rotational moulding process which produces a stress-free product. Furthermore, the Polymer used includes additives which make it resistant to harmful UV rays from the sun and with correct installation and general on-going care, these products have a long life ahead of them with very little or no maintenance required.

Specifications:
  • 1340 litre (295 galls) capacity
  • 2” fill point
  • 4” inspection hatch (screw cap)
  • 1” bottom outlet (top outlet tanks are available, contact us for more info)
Dimensions:
  • Diameter: 1250mm
  • Height: 1280mm
  • Weight: 40kg
Recommended Base Size:

We recommend along with current regulations a base size which extends 300mm all the way around the tank

  • Length: 1850mm
  • Width: 1850mm

You can call our sales team for product advice on 0330 999 1100 or more information about the regulations that surround oil storage can be found on the OFTEC website here

This tank is being sold at a reduced price, not because it is faulty, but due to the recent launching of an upgraded and more modern design of products, therefore Atlantis is phasing out a certain range of tanks.

Advice

No. Today, no openings (other than the tank outlet) are permitted below the maximum level of fuel in any oil tank. This reduces the risk of accidental spillage. In the event that contaminants (e.g. water) need to be removed from an oil tank, they should be removed by an appropriately licensed contractor via the inspection aperture fitted to the tank.


Related Products

All plastic oil tanks must be installed on a flat, level and fire resistant base capable of supporting the weight of the tank when fully laden. If concrete slabs are used, they should be a minimum of 50mm thick. The base should extend at least 300mm beyond the widest points of the tank and fully support the base of the tank in its entirety. Piers are not suitable for this purpose and can cause irreparable damage to the tank.


Related Products

Oil tanks with a nominal capacity not exceeding 3,500 litres should not be fitted any closer than 1.8 metres to a non-fire rated (30 minute minimum fire resistance) wall or eaves. Where these clearances cannot be achieved, the measures noted in British Standard BS5410 and OFTEC Technical Instruction Book 3 must be provided – i.e. the provision of a 30 minute (minimum) fire resistant wall which extends at least 300mm above and beyond the ends of the oil tank. It will be necessary to protect exposed eaves forming part of a roof within 1.8 metres of the top of an oil tank to provide a minimum of 30 minutes fire resistance. Cladding can be applied to the eaves in order to prevent fire from spreading to the roof.

For oil tanks with a capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

Oil tanks with a nominal capacity of less than 3,500 litres should not be placed within 1.8 metres of a flu outlet. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

If the oil tank has a nominal capacity of less than 3,500 litres, it should not be placed any closer than 760mm to a boundary. This assumes that there are no flu outlets or buildings between the tank and the boundary. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the oil tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

A single skin oil tank consists of a single container in which the fuel is stored. Unlike bunded oil tanks and bunded fuel tanks, single skin oil tanks incorporate no secondary containment. In the event of a spill, a pollution incident occurs.

Single skin oil tanks are not suitable for the storage of fuel at commercial, industrial or institutional premises, or at domestic installations with an installed capacity of over 2,500 litres – unless installed within a suitably bunded area.

For all other installations, an Oil Tank Risk Assessment must be undertaken by a competent person prior to installation and in accordance with the requirements of OFTEC Technical Instruction Book 3. In anticipation of possible future regulations, serious consideration should be given to fitting a bunded tank, even where a single skin tank may currently suffice.


Related Products

Delivery information

Collection Service

Collection is available from either our Durham, Kemble or Ely depots. We recommend you provide 24 hours notice so that we can prepare your order. In some circumstances, you may recieve a discount relating to the carriage cost element.

  • Collect from Durham, Kemble or Ely
  • Discounts Available
  • Quicker lead times
Ex-Works

The delivery and offloading of this product is dependent on location and site conditions. To obtain a delivery cost, please contact our sales team and provide a delivery postcode and confirm whether or not you have offloading facilities.

Reviews

There are no reviews yet.

Be the first to review “1340 Litre Vertical Plastic Single Skin Oil Tank”

There are no products in your basket.