1800 Litre Steel Bunded Oil Tank – TAN.BUS-1800
Tank & Bund:

An 1800 litre steel bunded oil tank which is suitable for both domestic and commercial applications.

The liquid is stored in the primary or inner tank and the outer tank forms the required bund with capacity for 110% of the primary tank’s capacity which makes this tank suitable for both domestic and commercial installations.  This tank is suitable for the storage of heating oil, kerosene, diesel, waste oils and many other liquids (please check before usage). A bunded tank is a tank within a tank, the outer tank provides protection for the inner tank which therefore makes it harder for the inner tank to fail.  However, in the unlikely event of the inner tank failing, the outer tank will provide secondary containment.

These tanks are manufactured to the highest standards and conform to BS799 pt5. The thickness of the steel used varies with tank size and all tanks are pressure tested before they leave the workshop. Furthermore, these tanks are painted with 2 coats of our specially formulated anti rust coating system designed to give maximum protection.  If you would like to purchase this paint separately, please click here.   We recommend painting your steel tank once a year to achieve the maximum lifespan.

This steel tank is a good option if you are wanting to deter any opportunist in oil theft which is very much on the rise currently, especially if the security lid option has been chosen.

Compliance:

This tank complies with: Oil Pollution Prevention Guidelines (England & Wales) 2002 PPG2 and BS799 pt5

Specifications:
  • 1800 litre (400 galls) capacity
  • 2” fill point
  • 2″ top socket as a spare connection
  • 1″ bottom outlet
  • 1.5″ port for a gauge
  • 1.5″ port for bund gauge
  • Tank to bund vent
  • Bund vent
  • 1″ top suction drain port
  • 50mm x 100mm full-length bearers
  • Pitched roof design
  • Small tin of “touch-up” paint for applying when scratches might occur during the installation process.
  • Standard Colour: Holly Green
Optional extras include:
  • Top outlet to replace bottom outlet (please contact our sales office if this option is required)
  • Apollo visual contents gauge or…
  • Clock face gauge or spiral float gauge (to see explainer video, please click here)
  • Bottom outlet fitting kit/filter & valve pack (economy or advanced, to see explainer video, please click here)
  • Mechanical overfill limiter spill stop device (if this is selected, please note that it will be fitted to the rear 2″ tank socket on the tank as it is only compatible with female threads and the front fill point has a male BSP thread)
  • The lockable lid which houses all top connections (excl. bund vent) within the lockable area (this could add lead time of up to 1 week)
  • Metal tank paint 1 litre (Green or Black depending on tank colour)
  • Steel tank maintenance pack (To get the maximum lifespan out of these steel tanks, we recommend you purchase our steel tank maintenance pack. View here. This will help keep your steel tank in prime condition) Includes: 1 Litre Metal Tank Paint, Brush & Roller, Gloves, Tank Sponge for absorbing water
  • An Extra top coat of paint can be applied before despatch (this could add an extra day onto the lead time)
  • Tank colour change: RAL or BS Colour must be provided with order. (this could add a lead time of up to 1 week)
Warranty:
  • 10-year warranty, each tank is provided with a warranty manual
Dimensions:
  • Length: 1320mm
  • Width: 1320mm
  • Height: 1220mm
  • Weight: 310kg
Recommended Base Size:

Full installation instructions are supplied with the tank.  We recommend along with current regulations a base size which extends 300mm all the way around the tank

  • Length: 1920mm
  • Width: 1920mm

You can call our sales team for product advice on 0330 999 1100 or more information about the regulations that surround oil storage can be found on the OFTEC website here

To view a product features video, please click here

Advice

Oil tanks with a nominal capacity not exceeding 3,500 litres should not be fitted any closer than 1.8 metres to a non-fire rated (30 minute minimum fire resistance) wall or eaves. Where these clearances cannot be achieved, the measures noted in British Standard BS5410 and OFTEC Technical Instruction Book 3 must be provided – i.e. the provision of a 30 minute (minimum) fire resistant wall which extends at least 300mm above and beyond the ends of the oil tank. It will be necessary to protect exposed eaves forming part of a roof within 1.8 metres of the top of an oil tank to provide a minimum of 30 minutes fire resistance. Cladding can be applied to the eaves in order to prevent fire from spreading to the roof.

For oil tanks with a capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

Oil tanks with a nominal capacity of less than 3,500 litres should not be placed within 1.8 metres of a flu outlet. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

If the oil tank has a nominal capacity of less than 3,500 litres, it should not be placed any closer than 760mm to a boundary. This assumes that there are no flu outlets or buildings between the tank and the boundary. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the oil tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

Delivery information

Collection Service

Collection is available from either our Durham, Kemble or Ely depots. We recommend you provide 24 hours notice so that we can prepare your order. In some circumstances, you may recieve a discount relating to the carriage cost element.

  • Collect from Durham, Kemble or Ely
  • Discounts Available
  • Quicker lead times
Parcel

For our smaller items, a third party parcel service is used. Goods are wrapped and dispatched the same day and sent on a next day service. Orders must be received before 1pm for same day dispatch.

  • Same day dispatch
  • Next day service
  • Order before 1pm
  • £8.95 ex VAT per parcel (Free for orders over £150 ex VAT)
Pre 10.30am Next Day Parcel

For our smaller items, a third party parcel service is used. Goods are wrapped and dispatched the same day and sent on a pre-10.30am next day service. Orders must be received before 12pm for same day dispatch.

  • Same day despatch
  • Next day pre 10.30am delivery
  • Order by 12pm

Reviews

There are no reviews yet.

Be the first to review “1800 Litre Steel Bunded Oil Tank”

Other products you may be interested in

There are no products in your basket.