1350 Litre Steel Bunded Waste Oil Tank

Rated 0 out of 5
(0 reviews)

10 to 15 working days

This tank has required accessories which must be added before you can add to basket.

Description

1350 Litre Steel Bunded Waste Oil Tank – WOS.1350
Tank & Bund:

A 1350 litre steel bunded waste oil tank which is suitable for commercial applications.

The liquid is stored in the primary or inner tank and the outer tank forms the required bund with capacity for 110% of the primary tank’s capacity which makes this tank suitable for both domestic and commercial installations.  This tank is suitable for the storage of heating oil, kerosene, diesel, waste oils and many other liquids (please check before usage). A bunded tank is a tank within a tank, the outer tank provides protection for the inner tank which therefore makes it harder for the inner tank to fail.  However, in the unlikely event of the inner tank failing, the outer tank will provide secondary containment.

These tanks are manufactured to the highest standards and conform to BS799 pt5. The thickness of the steel used varies with tank size and all tanks are pressure tested before they leave the workshop. Furthermore, these tanks are supplied with one coat primer and one top coat which is normally green in colour as standard.   We recommend painting your steel tank once a year to achieve the maximum lifespan.

Compliance:

This tank complies with: Oil Pollution Prevention Guidelines (England & Wales) 2002 PPG2 and BS799 pt5

Specifications:
  • 1350 litre (300 galls) capacity
  • 2 x 2” ports
  • 1 x 2″ internal suction port
  • 1.5″ port for inner tank gauge
  • 1.5″ port for bund gauge
  • Tank vent
  • 300mm square lockable hinged lid
  • 300mm square strainer
  • Lifting eyes
  • 50mm x 100mm full-length bearers
  • Small tin of “touch-up” paint for applying when scratches might occur during the installation process.
  • Standard Colour: Black
Warranty:
  • 10-year warranty
Dimensions:
  • Length: 1930mm
  • Width: 710mm
  • Height: 1220mm
  • Weight: 275kg

Advice

Oil storage tanks should never be installed in a habitable area. If installed internally, they should always be contained within an enclosed chamber. Detailed requirements exist for internal oil storage installations. For more information contact your local Building Control Officer or OFTEC.


Related Products

Oil tanks with a nominal capacity not exceeding 3,500 litres should not be fitted any closer than 1.8 metres to a non-fire rated (30 minute minimum fire resistance) wall or eaves. Where these clearances cannot be achieved, the measures noted in British Standard BS5410 and OFTEC Technical Instruction Book 3 must be provided – i.e. the provision of a 30 minute (minimum) fire resistant wall which extends at least 300mm above and beyond the ends of the oil tank. It will be necessary to protect exposed eaves forming part of a roof within 1.8 metres of the top of an oil tank to provide a minimum of 30 minutes fire resistance. Cladding can be applied to the eaves in order to prevent fire from spreading to the roof.

For oil tanks with a capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

Oil tanks with a nominal capacity of less than 3,500 litres should not be placed within 1.8 metres of a flu outlet. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

If the oil tank has a nominal capacity of less than 3,500 litres, it should not be placed any closer than 760mm to a boundary. This assumes that there are no flu outlets or buildings between the tank and the boundary. Where these distances cannot be achieved, the protection measures noted in OFTEC Technical Instruction Book 3 and British Standard BS5410 must be provided by means of a 30 minute fire resistant wall which extends a minimum of 300mm above and beyond the ends of the oil tank. For oil tanks with a nominal capacity of 3,500 litres or greater, please contact your local Building Control Officer or OFTEC.


Related Products

A bunded tank consists of a ‘tank within a tank’. In the event of a spillage, surplus liquid collects in the outer tank (or ‘bund’), thus averting a pollution incident. Bunded tanks are now required at commercial, industrial, institutional and most domestic premises.


Related Products

Delivery information

Standard Delivery

Our standard delivery service offers a 2-5 day service. We always aim to deliver using our own transport but may sometimes use a third party carrier should circumstances dictate. This is a kerbside delivery service and includes offload

  • 2-5 day service
  • Own transport (where possible)
  • Kerbside delivery
  • Includes offload
Collection Service

Collection is available from either our Durham or Ely depots. We recommend you provide 24 hours notice so that we can prepare your order. In some circumstances, you may recieve a discount relating to the carriage cost element.

  • Collect from Durham or Ely
  • Discounts Available
  • Quicker lead times